Omron HCG-801 Manuale Utente

Navigare online o scaricare Manuale Utente per no Omron HCG-801. Omron HCG-801 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 128
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Portable ECG Monitor
Model HCG-801
INSTRUCTION MANUAL
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.
ESPAÑOL
ENGLISH
Vedere la pagina 0
1 2 3 4 5 6 ... 127 128

Sommario

Pagina 1 - INSTRUCTION MANUAL

Portable ECG MonitorModel HCG-801INSTRUCTION MANUALCaution: Federal (USA) law restricts this device to sale by or on the order of a physician.ESPAÑOLE

Pagina 2 - TABLE OF CONTENTS

MAIN UNIT Display:The screen is used to display basic instructions and results of ECG readings, to adjust settings, and toreview ECG data stored on th

Pagina 3

CONTRASTEPresione el botón o el botón para ajustar el contraste. El contraste se puede configurar en uno de nueve niveles.El contraste aumenta a med

Pagina 4 - SAVE THESE INSTRUCTIONS

IDIOMAPresione el botón o el botón para seleccionar el idioma deseado, luego presione el botónSELECT (Seleccionar) para confirmar su selección. AJUS

Pagina 5

AJUSTE DE LAS CONFIGURACIONESE38FORMATO DE FECHAPuede seleccionar uno de los cuatro formatos, MM/DD/AA HH:MM (AM/PM), MM/DD/AA HH:MM(reloj de 24 horas

Pagina 6 - IMPORTANT SAFETY NOTES

MENSAJEEste parámetro especifica si se debe mostrar u ocultar el mensaje de descripción de datos.Presione el botón o el botón para resaltar la opció

Pagina 7

SOBREESCRIBIRLa unidad sobrescribe la lectura guardada más antigua cuando la tarjeta de memoria SD o la memoria de launidad se llene. Un mensaje le ad

Pagina 8

CÓMO BORRAR LOS DATOS DEL ECGCómo borrar todos los datos del ECGPuede usar el menú SET (Configurar) para borrar todos los datos del ECG guardados en l

Pagina 9

3. Presione el botón y seleccione Sí, luego presione el botón SELECT(Seleccionar). Se visualiza la cantidad de conjuntos de datos que se desea borra

Pagina 10 - KNOW YOUR UNIT

4. Presione el botón SELECT (Seleccionar). Aparece el mensaje de confirmación “¿Borrar los datos seleccionados?”.5. Presione el botón para seleccion

Pagina 11

COPIA DE LOS DATOS EN UNA TARJETA DE MEMORIA SDSe pueden copiar los datos del ECG de la memoria interna de la unidad en una tarjeta de memoria SD. Est

Pagina 12

4. Presione el botón SELECT (Seleccionar). Los datos del ECG se copian en la tarjeta de memoria SD.PRECAUCIÓN: Nunca retire la tarjeta de memoria SD m

Pagina 13 - Operating Instructions

MAIN UNIT Display:ECG GraphThis screen is displayed when you use the GRAPH menu to select ECG data stored on the unit.KNOW YOUR UNIT11NOTE: During mea

Pagina 14 - BATTERY LIFE AND REPLACEMENT

COPIA DE LOS DATOS DESDE LA TARJETA DE MEMORIA SD A UNA PCSiga estas instrucciones para copiar datos desde la tarjeta de memoria SD a una PC.1. Asegúr

Pagina 15 - START button side

COPIA DE LOS DATOS DESDE UNA PC A LA TARJETA DE MEMORIA SD Siga estas instrucciones para copiar datos desde una PC a la tarjeta de memoria SD.1. Asegú

Pagina 16 - HOW TO SET THE DATE AND TIME

E48Esta sección incluye una lista de todos los mensajes que pueden aparecer en pantalla. Consulte estosmensajes si no está seguro de lo que significa

Pagina 17

MENSAJE DE FRECUENCIA CARDÍACAHR: Además de los mensajes anteriores, la unidad muestra la frecuencia cardíaca en latidos por minuto.MENSAJES DE ACCIÓN

Pagina 18 - HOW TO USE THE SD MEMORY CARD

Analizando.Se están analizando los datos delECG.No es necesario llevar a caboninguna acción. Espere hasta quefinalice el análisis.MENSAJESE50MENSAJE C

Pagina 19

MENSAJESE51MENSAJE CAUSA CORRECCIÓNGuardando datos en la memoriaSD.NO BORRE LA MEMORIA SD.Los datos del ECG se estánescribiendo (guardando) en latarje

Pagina 20

MENSAJESE52MENSAJE CAUSA CORRECCIÓNConfigure el reloj.Las pilas están agotadas y laconfiguración de fecha y hora dela unidad ha desaparecido.Coloque p

Pagina 21

MENSAJESE53MENSAJE CAUSANRO. DE ERRORCORRECCIÓNError al formatear lamemoria SD.Se ha producido un error alformatear la tarjeta de memoriaSD.24Use una

Pagina 22

E54PROBLEMA CAUSA SOLUCIÓNNo pasa nada cuando se presionael botón ON/OFF / STOP(Encendido/Apagado / Detener).Las pilas están agotadas.Las pilas están

Pagina 23

SOLUCIÓN DE PROBLEMASE55PROBLEMA CAUSA SOLUCIÓNLos datos del ECG handesaparecido.Las pilas están agotadas o se hanretirado durante más de unahora.La u

Pagina 24

KNOW YOUR UNIT12COMPONENTS:• SD memory card• (801SDMEMORY)• Storage pouch• (801STORAGEPOUCH)• Instruction Manual• (HCG801INST)• 2 LR03(AAA)Batteries•

Pagina 25 - HOW TO TAKE A MEASUREMENT

• Limpie la unidad con un paño humedecido con agua o detergentesuave. Luego séquela con un paño seco.• Limpie los electrodos usando un paño humedecido

Pagina 26

PRECAUCIÓN:• No lave esta unidad con agua. • No guarde la unidad en las siguientes condiciones ambientales:- Lugares expuestos a la luz directa del so

Pagina 27

NOTA:POTENCIAL DE INTERFERENCIA DE RADIO/TELEVISIÓN (para EE.UU. solamente)Este producto ha sido probado y cumple con los límites de un dispositivo di

Pagina 28

Se garantiza que el monitor de ECG HCG-801, salvo la tarjeta de memoria SD y la bolsa dealmacenamiento, no presentarán defectos en materiales y mano d

Pagina 29

ESPECIFICACIONESE60Modelo: HCG-801Sistema de inducción: Canal único bipolar Frecuencia cardíaca promedio: 2 a 200 latidos/min.Ancho de banda: 0.05

Pagina 30 - HOW TO DISPLAY ECG DATA

FECHADE LA MEDICIÓNHORADE LA MEDICIÓNANOTE AQUÍ SUS SÍNTOMASREGISTRO DE SÍNTOMAS DE MUESTRASe recomienda hacer fotocopias de este registro y utilizarl

Pagina 31

E62FECHADE LA MEDICIÓNHORADE LA MEDICIÓNANOTE AQUÍ SUS SÍNTOMAS

Pagina 33

Fabricado por Omron HealthcareHecho en JapónDistribuido porOMRON HEALTHCARE, INC.1200 Lakeside DriveBannockburn, Illinois 60015www.omronhealthcare.com

Pagina 34

1. Slide the battery cover in the direction of the arrow, and lift the end ofthe cover upwards. NOTE: Do not pull hard on the cover.2. Insert two LR03

Pagina 35

BATTERY LIFE AND REPLACEMENTWhen the “Please insert new batteries.” message appears, replace both batteries with new ones.• Always turn the unit off

Pagina 36

If the battery cover is accidentally detached, attach the battery cover as described in theprocedure below. 1. Align the pin of the battery cover with

Pagina 37

Always set the date and time before using the unit for the first time. Check that date and time are correct before using the unit, reset them if neces

Pagina 38

3. Press the SELECT button to confirm the month setting. The month setting is set and the day setting is highlighted.The display cycles through the s

Pagina 39

The unit includes an SD memory card for storing ECG data, which can then be viewed by your doctor later.This section describes how to insert and eject

Pagina 40

2. Open the SD memory card slot cover and insert the SD memory cardinto the slot. NOTES:• Check that the card is correctly aligned and insert it into

Pagina 41 - ERASING ECG DATA

2Before Using the UnitIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 42 - Erasing Selected ECG Data

3. Close the SD memory card slot cover. HOW TO USE THE SD MEMORY CARD20

Pagina 43

To eject the SD memory card1. Check that the unit is turned off.CAUTION: Eject an SD memory card only when the unit is turned off.2. Open the SD memor

Pagina 44

FORMATTING AN SD MEMORY CARDYou will need to format the SD memory card before you use it for the first time, and in the followingcircumstances. • If

Pagina 45

3. Press the SELECT button. The message “All data in SD will be deleted. Format SD?” is displayed. 4. Press the button to select YES, then press the

Pagina 46

In order to obtain a good ECG reading, it is important that measurements are taken correctly. Before taking a measurement for the first time, read the

Pagina 47

1. Press the ON/OFF / STOP button to turn the unit on. The unit displays the following reminder. “Self-measurement is not thesame as medical diagnosis

Pagina 48 - MESSAGES

4. Place the chest electrode on bare skin about 2 inches below your left nipple (IMPORTANT - see belowfor female application).NOTE:• Make sure that yo

Pagina 49

5. While maintaining the same posture, press the START button. The measurement takes about 30 seconds to complete. The unit beeps every second during

Pagina 50

A data description message is displayed when the measurement has beencompleted. (Refer to page 48 - 49 for details.) When the SD momory card is insert

Pagina 51

COMMON CAUSES OF INACCURATE MEASUREMENT RESULTSThe following situations can result in inaccurate measurement results or errors.HOW TO TAKE A MEASUREME

Pagina 52

How to Erase, Save and Organize ECG Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41Erasing ECG Data

Pagina 53

The GRAPH menu is used to display the list of ECG data stored on the SD memory card or in unitmemory. 1. Press the MENU button while the unit is turne

Pagina 54 - TROUBLE SHOOTING

Press the button to move down the list, and the button to move up. The most recent measurement result is displayed at the top of the list and is aut

Pagina 55

You can use the SET menu to adjust various settings.You can press the START button to begin measurement even while the SET menu is displayed.BASIC OPE

Pagina 56 - MAINTENANCE AND STORAGE

4. Press the button or button to select the desired setting, then press the SELECT button tosee the options for that setting. 5. Adjust the settings

Pagina 57

DATE AND TIME Select this item if you need to reset the date and time. For details on setting the date and time, refer to page 16.NOTE: You will be p

Pagina 58 - FCC STATEMENT

BRIGHTNESS Press the button or button, to adjustthe brightness. The brightness can be set to one of nine levels.Brightness increases as the marker

Pagina 59 - WARRANTY INFORMATION

CONTRASTPress the button or button to adjust the contrast. Contrast can be set to one of nine levels.Contrast increases as the marker moves to the

Pagina 60 - SPECIFICATIONS

LANGUAGE Press the button or button to select the desired language, then press the SELECT button toconfirm your selection. HOW TO ADJUST THE SETTING

Pagina 61 - SAMPLE SYMPTOM LOG

HOW TO ADJUST THE SETTINGS38DATE FORMATYou can select one of four formats, MM/DD/YY HH:MM (AM/PM), MM/DD/YY HH:MM (24 hourclock), DD/MM/YY HH:MM (AM/P

Pagina 62 - WRITE DOWN YOUR SYMPTOMS HERE

MESSAGEThis setting specifies whether to display or hide the data description message. Press the button or button to highlight the Display or Hide,

Pagina 63

4Thank you for purchasing the OMRON®Portable ECG Monitor.INTRODUCTIONFill in for future reference.DATE PURCHASED:________________SERIAL NUMBER: ______

Pagina 64

OVERWRITE The unit will overwrite the oldest stored reading when the SD memory card or unit memory is full. A message will warn that this will happen,

Pagina 65 - MANUAL DE INSTRUCCIONES

ERASING ECG DATAErasing All ECG DataYou can use the SET menu to erase all the ECG data stored on the SD memory card or in unit memory. NOTE: If an SD

Pagina 66 - Antes de usar la unidad

3. Press the button and select YES, then press the SELECT button. The number of sets of data to be deleted is displayed.4. Press the button and sel

Pagina 67 - Cuidado y mantenimiento

4. Press the SELECT button. The confirmation message “Erase selected data?” is displayed.5. Press the button to select YES, then press the SELECT but

Pagina 68 - GUARDE ESTAS INSTRUCCIONES

COPYING DATA TO AN SD MEMORY CARDYou can copy ECG data from the unit’s internal memory to an SD memory card. This allows you to copydata to the SD mem

Pagina 69

4. Press the SELECT button. The ECG data is copied to the SD memory card.CAUTION: Never remove the SD memory card while data is beingcopied to it. If

Pagina 70 - PRECAUCIÓN

COPYING DATA FROM THE SD MEMORY CARD TO A PCPlease follow these instructions to copy data from the SD memory card to a PC.1. Make sure the PC is equip

Pagina 71

COPYING DATA FROM A PC TO THE SD MEMORY CARDPlease follow these instructions to copy data from a PC to the SD memory card.1. Make sure the PC is equip

Pagina 72

48This section includes a list of all messages that may appear on the display. Refer to these if you are not surewhat a displayed message means.DATA D

Pagina 73 - CONOZCA SU UNIDAD

HEART RATE MESSAGEHR - In addition to the above messages the unit will display the heart rate in beats per minute.ACTION MESSAGESFinally, the unit wil

Pagina 74

The heart is a muscular pump controlled by electrical impulses generated by the body. It is divided into twosides by the septa and each side has two c

Pagina 75

Analyzing. The ECG data is being analyzed.No action required. Wait untilanalysis ends.MESSAGES50MESSAGE CAUSE CORRECTIONCannot measure. Please follow

Pagina 76

MESSAGES51MESSAGE CAUSE CORRECTIONStoring on SD memory.DO NOT REMOVE SDECG data is being written(saved) to the SD memory card.Wait until the message d

Pagina 77

MESSAGES52MESSAGE CAUSE CORRECTIONSet clock.The battery power has run lowand the Date and Time setting onthe unit has disappeared.Insert new batteries

Pagina 78 - Vida útil de la pila:

MESSAGES53MESSAGE CAUSEERROR # CORRECTIONError formatting SDmemory.An error occurred whenformatting the SD memory card.24Use a new/different SD memory

Pagina 79 - START (Inicio)

54PROBLEM CAUSE SOLUTIONNothing happens when you pressthe ON/OFF / STOP button.The batteries are worn out.The batteries are insertedincorrectly.Replac

Pagina 80

TROUBLE SHOOTING55PROBLEM CAUSE SOLUTIONECG data has disappeared.The batteries are worn out orhave been removed for over onehour.The unit will not be

Pagina 81

• Clean the unit with a cloth dampened with water or mild detergent.Then wipe it dry with a dry cloth. Do not wipe the SD memory cardslot cover. • Wip

Pagina 82

CAUTION:• Do not wash the unit with water. • Do not store the unit in the following ambient conditions:- Locations exposed to direct sunlight. - Locat

Pagina 83

NOTE:POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)This product has been tested and found to comply with the limits for a Class B digit

Pagina 84

Your Portable ECG Monitor HCG-801, excluding the SD memory card and storage pouch, is warranted tobe free from defects in materials and workmanship ap

Pagina 85

6IMPORTANT SAFETY NOTESTo assure the correct use of the product basic safety measures should always be followed including thewarnings and cautions lis

Pagina 86

SPECIFICATIONS60Model: HCG-801Induction system: Bipolar single channel Heart rate range: 2 to 200 beats/min.Bandwidth: 0.05 to 40HzSampling Rate:

Pagina 87

MEASUREMENTDATEMEASUREMENTTIMEWRITE DOWN YOUR SYMPTOMS HERESAMPLE SYMPTOM LOGYou may wish to make photocopies of this log and use them to fill in any

Pagina 88

62MEASUREMENTDATEMEASUREMENTTIMEWRITE DOWN YOUR SYMPTOMS HERE

Pagina 90

Manufactured by Omron HealthcareMade in JapanDistributed by:OMRON HEALTHCARE, INC.1200 Lakeside DriveBannockburn, Illinois 60015www.omronhealthcare.co

Pagina 91

Monitor Portátil de ECGModelo HCG-801MANUAL DE INSTRUCCIONESPrecaución: Las leyes federales de EE.UU. establecen que este dispositivo sólo puede ser v

Pagina 92

E2Antes de usar la unidadIntroducción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 93

E3Cómo borrar, guardar y organizar los datos del ECG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E41Cómo borrar los dat

Pagina 94

E4Gracias por adquirir el monitor portátil de ECG de OMRON®.INTRODUCCIÓNComplete lo siguiente para consulta futura.FECHA DE COMPRA:_______________NÚME

Pagina 95

El corazón es una bomba muscular controlada por impulsos eléctricos generados por el cuerpo. Se dividepor la mitad mediante el septo y cada mitad tien

Pagina 96 - CÓMO AJUSTAR LOS VALORES

WARNING:Do not use this device on people with sensitive skin or allergies. Do not attempt to use the device over or through clothing.Do not attempt t

Pagina 97

E6NOTAS DE SEGURIDAD IMPORTANTESPara garantizar el uso correcto del producto, siempre se debe cumplir con las medidas de seguridad básicas,incluyendo

Pagina 98

ADVERTENCIA:No use este dispositivo en personas con piel sensible o que sufran alergias. No intente usar el dispositivo sobre o a través de la ropa.N

Pagina 99

PRECAUCIÓN:No use la unidad con ningún otro propósito que no sea el de obtener una electrocardiografía.No exponga la unidad a vibraciones o golpes fue

Pagina 100 - AJUSTE DE LAS CONFIGURACIONES

PantallaMuestra el patrón de la onda ymuestra los menúes, mensajesy opciones de mostrar.BotónMueve el patrón de onda o menúdeseado hacia la izquierda

Pagina 101

UNIDAD PRINCIPAL Pantalla:La pantalla se usa para visualizar instrucciones básicas y resultados de las lecturas del ECG, para ajustarconfiguraciones y

Pagina 102

UNIDAD PRINCIPAL Pantalla:Gráfico del ECGEsta pantalla se visualiza cuando utiliza el Menú GRAPH (Gráfico) para seleccionar los datos del ECG quese gu

Pagina 103

CONOZCA SU UNIDADE12COMPONENTES:• Tarjeta de memoria SD• (801SDMEMORY)• Bolsa de almacenamiento• (801STORAGEPOUCH)Monitor Portátil de ECGModelo HCG-80

Pagina 104

1. Deslice la tapa del compartimiento de las pilas en la dirección queindica la flecha, y levante el extremo de la tapa hacia arriba. NOTA: No ejerza

Pagina 105 - CÓMO BORRAR LOS DATOS DEL ECG

VIDA ÚTIL Y CAMBIO DE LAS PILASCuando aparece el mensaje “Please insert new batteries” (Coloque pilas nuevas), cambie ambas pilas porpilas nuevas.• A

Pagina 106

Si la tapa del compartimiento de las pilas se saleaccidentalmente, cuelgue la tapa delcompartimiento como se describe en elprocedimiento que aparece a

Pagina 107

CAUTION:Do not use for any purpose other than obtaining an electrocardiograph.Do not expose the unit to strong shocks or vibrations. Do not drop or st

Pagina 108

Configure siempre la fecha y hora antes de usar la unidad por primera vez. Verifique si la fecha y hora son correctas antes de usar la unidad, y conti

Pagina 109

3. Presione el botón SELECT (Seleccionar) para confirmar laconfiguración del mes. Se establece la configuración del mes y la configuración del díaapa

Pagina 110

La unidad incluye una tarjeta de memoria SD para guardar los datos del ECG, para que su médico puedaverlos posteriormente. Esta sección describe cómo

Pagina 111

2. Abra la tapa de la ranura de la tarjeta de memoria SD y coloque unatarjeta de memoria SD en la ranura. NOTAS:• Verifique que la tarjeta esté correc

Pagina 112 - MENSAJES

3. Cierre la tapa de la ranura de la tarjeta de memoria SD. USO DE LA TARJETA DE MEMORIA SDE20

Pagina 113

Cómo sacar la tarjeta de memoria SD1. Verifique que la unidad esté apagada.PRECAUCIÓN: Retire solamente la tarjeta de memoria SD cuando la unidad está

Pagina 114

CÓMO FORMATEAR UNA TARJETA DE MEMORIA SDUsted debe formatear la tarjeta de memoria SD antes de usarla por primera vez y en las siguientescircunstancia

Pagina 115

3. Presione el botón SELECT (Seleccionar). Se visualiza el mensaje “Se borrarán todos los datos de la SD.¿Formatear SD?” 4. Presione el botón para

Pagina 116

Para obtener una lectura de ECG de buena calidad, es importante que las mediciones se tomencorrectamente. Antes de tomar una medición por primera vez,

Pagina 117

1. Presione el botón ON/OFF / STOP (Encendido/Apagado / Detener)para encender la unidad. La unidad pone en pantalla el siguiente recordatorio. “Self-m

Pagina 118 - SOLUCIÓN DE PROBLEMAS

Chest electrodePlace this against yourchest when taking ameasurement.DisplayDisplays the wave pattern anddisplays menus, messages anddisplay options.M

Pagina 119

4. Coloque el electrodo del tórax sobre la piel desnuda alrededor de 5 cm por debajo de la tetilla izquierda(IMPORTANTE: vea más adelante las instrucc

Pagina 120

5. Mientras está en la misma posición, presione el botón START (Inicio). La medición tarda alrededor de 30 segundos para completarse. La unidad emite

Pagina 121 - PRECAUCIÓN:

Se demuestra un mensaje de descripción de datos una vez que lamedición se haya completado. (Consulte las páginas 48 - 49 para obtenerinformación más d

Pagina 122 - DECLARACIÓN DE LA FCC

CAUSAS COMUNES DE RESULTADOS INEXACTOS DE MEDICIÓNLas siguientes situaciones pueden dar como resultado mediciones imprecisas o errores.CÓMO TOMAR UNA

Pagina 123 - INFORMACIÓN SOBRE LA GARANTÍA

El menú GRAPH (Gráfico) se usa para visualizar la lista de los datos del ECG que se guardan en la tarjetade memoria SD o en la memoria de la unidad. 1

Pagina 124 - ESPECIFICACIONES

Presione el botón para recorrer la lista hacia abajo y el botón para recorrer la lista haciaarriba. El resultado de la medición más reciente aparece

Pagina 125

Puede usar el menú SET (Configurar) para ajustar diversos valores.Puede presionar el botón START (Inicio) para comenzar con la medición incluso mientr

Pagina 126 - ANOTE AQUÍ SUS SÍNTOMAS

4. Presione el botón o el botón para seleccionar la configuración deseada, luego presione elbotón SELECT (Seleccionar) para ver las opciones para es

Pagina 127

FECHA Y HORASeleccionar este elemento si necesita volver a configurar la fecha y hora. Para obtener más detalles conrespecto a la configuración de fec

Pagina 128 - HCG801INST Rev 1657513-0A

BRILLOPresione el botón o el botón para ajustar el brillo. El brillo se puede configurar en uno de los nueve niveles.El brillo aumenta a medida que

Commenti su questo manuale

Nessun commento