2 Intelligent Flag I/II V600-HA
Intelligent Flag I/II
V600-HA
Innovative RFID Electronic Flags to
Replace Mechanical Flag and Kanban
Systems
• Doesn't need a program and can be used like a sensor.
• Advanced line construction at minimal cost.
• Saves space.
• Precise installation not required (Transmission distance:
100 mm max.).
• A verification function provided on multi-functional type.
• Addition of 16-bit models to the series responds to applica-
tions from Kanban to quality control.
• Equipped with a wiring reduction mode and communications
parity check function (16-bit models).
• Both NPN and PNP output available.
• FCC certified.
Ordering Information/Specifications
Amplifier
Type Read-only (8-bit) Multi-functional (8-bit) Read-only (16-bit)
Item Model V600-HAR91 V600-HAR81 V600-HAM91 V600-HAM81 V600-HAR92
Power supply 24 VDC ±10%, ripple (p-p): 10%
Current consumption 130 mA max.
Input Transistor output or contact output
Short-circuit current: 3 mA (typical) (IN terminal and 0-V short-circuit)
OFF voltage: 15 to 30 VDC
ON voltage: 0 to 5 VDC
Input impedance: 8.2 k
Applied voltage: 30 VDC max.
Transistor output
OFF voltage:
15 to 30 VDC
Input impedance:
8.2 k
Short-circuit current:
3 mA (typical) (for 0-V short-circuit of
INHIBIT/TRG)
ON voltage:
0 to 5 VDC
Applied voltage:
30 VDC max.
Output
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
PNP open collector
output, 20 mA max.
at 30 VDC, residual
voltage: 2 V max.
NPN open collector
output, 20 mA max. at
30 VDC, residual volt-
age: 2 V max.
PNP open collector out-
put, 20 mA max. at 30
VDC, residual voltage: 2 V
max.
NPN open collector output, 20 mA
max. at 30 VDC, residual voltage: 2 V
max.
Diagnostic functions Checks for CPU errors and transmission errors
Insulation resistance 50 M max. (at 500 VDC) between cable terminals and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between cable terminals and case (leakage current: 1 mA max.)
Vedere la pagina 0
1 2 3 4 5 6 ... 14 15

Sommario

Pagina 1 - Intelligent Flag I/II

2 Intelligent Flag I/II V600-HAIntelligent Flag I/IIV600-HAInnovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems• Doesn'

Pagina 2 - ■ Interface Cable

Intelligent Flag I/II V600-HA 11DimensionsNote: All units are in millimeters unless otherwise indicated.AmplifierV600-HAR91/-HAR81* Enlarged Section o

Pagina 3 - ■ Sensor

12 Intelligent Flag I/II V600-HAV600-HAM91/-HAM81* Enlarged Section of Mounting HoleTwo mounting holes *Vinyl-insulated round cord 5.8-mm dia., 23-con

Pagina 4 - System Configuration

Intelligent Flag I/II V600-HA 13V600-HAR92SensorV600-HS51V600-HS61XG4E-263130˚4.45.5302117.528.336.361.844.3898.29868.57555308035.2500 mm28.152.325625

Pagina 5 - Characteristic Data (Typical)

14 Intelligent Flag I/II V600-HAV600-HS63V600-HS67Interface CableV600-A6@R (for V600-HAR91/-HAR81))51.510205327 640 282311551813513.8 dia.Two, 4.5-dia

Pagina 6 - V600-HA 7

Intelligent Flag I/II V600-HA 15V600-A6@M (for V600-HAM91/-HAM81/-HAR92)Model L (m)V600-A60R/60M 2V600-A61R/61M 5V600-A62R/62M 10Vinyl-insulated round

Pagina 7 - ■ Transmission Time

16 Intelligent Flag I/II V600-HA Terms and ConditionsWARRANTY, LIMITATIONS OF LIABILITYWARRANTY OMRON’s exclusive warranty is that the product

Pagina 8 - Precautions

Intelligent Flag I/II V600-HA 3Note: The connector is not waterproof. If there is a possibility that the connector may be exposed to water, keep it in

Pagina 9 - ■ Correct Use

4 Intelligent Flag I/II V600-HA Sensor Transmission Distance SpecificationsRecommended CombinationsNote: 1. The specifications take fluctuations in

Pagina 10 - Dimensions

Intelligent Flag I/II V600-HA 5System ConfigurationProgrammable Controller, I/O terminal, B7A, CompoBus/S, etc. Sensor ControllerV600-A6R V600-A6MIn

Pagina 11 - V600-HAM91/-HAM81

6 Intelligent Flag I/II V600-HACharacteristic Data (Typical) Transmission RangeCombinations with the V600-HS51 SensorCombinations with the V600-HS61

Pagina 12 - V600-HA 13

Intelligent Flag I/II V600-HA 7Combinations with the V600-HS63 SensorX0–10–20–30 1020301020 30YYX0–10–20–30–40 10 20 30 40YX102030XY0–10–20–30–40–50 1

Pagina 13 - Interface Cable

8 Intelligent Flag I/II V600-HACombinations with the V600-HS67 Sensor Transmission TimeThe transmission time refers to the time required for communic

Pagina 14 - V600-HA 15

Intelligent Flag I/II V600-HA 9Circuit ConfigurationV600-HAR91V600-HAM91Input CircuitOutput CircuitV600-HAR92Input CircuitOutput CircuitV600-HAR81V600

Pagina 15 - Terms and Conditions

10 Intelligent Flag I/II V600-HAPower Supply VoltageDo not impose any voltage exceeding the rated voltage range. Doingso, or applying alternating curr

Commenti su questo manuale

Nessun commento