Omron M3 Manuale Utente

Navigare online o scaricare Manuale Utente per Sfigmomanometro digitale Omron M3. Omron M3 User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Manufacturer
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto,
617-0002
JAPAN
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
www.omron-healthcare.com
Production facility
Site de production
Produktionsstätte
Stabilimento di produzione
Oficina de producción
Productiefaciliteit
Производственное подразделение
OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD.
Binh Duong Province, VIETNAM
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG U.K.
Subsidiary
Succursale
Niederlassung
Consociata
Empresa filial
Dochteronderneming
Дочерняя компания
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a, 68163 Mannheim, GERMANY
www.omron-medizintechnik.de
OMRON
SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Uniquement pour le marché français: OMRON Service Après Vente
Nº Vert 0 800 91 43 14
www.omron-sante.fr/contact
Prodotto in Vietnam
Сделано во ВьетнамеHergestellt in Vietnam
Geproduceerd in VietnamFabriqué en Vietnam
Fabricado en Vietnam
Made in Vietnam
Digital Automatic Blood Pressure Monitor
Model M3
Instruction Manual
English
Français
Deutsch
Italiano
Español
Nederlands
IM-HEM-7200-E(V)-03-10/2010
5329530-9B
Русский
Check following components!
Vérifier les composants suivants !
Prüfen Sie folgende Teile des Lieferumfangs!
Controllare i componenti indicati di seguito!
¡Compruebe los siguientes componentes!
Controleer de volgende onderdelen!
Проверьте следующие компоненты!
Digital Automatic Blood Pressure Monitor
Model M3
Instruction Manual
English
Français
Deutsch
Italiano
Español
Nederlands
IM-HEM-7200-E(V)-05-11/2011
5329530-9D
Русский
Vedere la pagina 0
1 2 3 4 5 6 ... 25 26

Sommario

Pagina 1 - Instruction Manual

ManufacturerOMRON HEALTHCARE Co., Ltd.53, Kunotsubo, Terado-cho, Muko, Kyoto,617-0002 JAPANEU-representativeOMRON HEALTHCARE EUROPE B.V.Scorpius 33, 2

Pagina 2 - Contents

83. Using the Unit3.3Taking a ReadingNotes:• To cancel a measurement, press the O/I START button to turn off the unit and to release the air in the ar

Pagina 3 - Important Safety Information

93. Using the UnitEN2. Remove the arm cuff.3. Press the O/I START button to turn off the monitor.The monitor automatically stores the measurement in i

Pagina 4

103. Using the Unit3.4Using the Memory FunctionThe monitor automatically stores the result up to 60 sets. It can also calculate an average reading bas

Pagina 5 - 1. Overview

113. Using the UnitENTo delete all the values stored in memoryWhen the memory symbol ( ) appears, first press the Memory button. Then while holding it

Pagina 6 - 2. Preparation

124.Troubleshooting and Maintenance4.1The Icons and Error MessagesError Display Cause RemedyIrregular or weak pulses are detected.Remove the arm cuff.

Pagina 7

134. Troubleshooting and MaintenanceENNote:The irregular heartbeat symbol ( ) may also be displayed with error messages.Cuff is under inflated.Careful

Pagina 8

144. Troubleshooting and Maintenance4.2TroubleshootingProblem Cause RemedyThe reading is extremely low (or high).Arm cuff not applied correctly.Apply

Pagina 9 - How to Sit Correctly

154. Troubleshooting and MaintenanceENNothing happens when you press the buttons.The batteries are empty.Replace the batteries with new ones.Refer to

Pagina 10 - Taking a Reading

164. Troubleshooting and Maintenance4.3MaintenanceTo protect your unit from damage, please observe the following:• Do not subject the main unit and th

Pagina 11 - 2. Remove the arm cuff

174. Troubleshooting and MaintenanceEN4.4StorageKeep the unit in its storage case when not in use.1. Unplug the air tube from the air connector.2. Gen

Pagina 12 - Using the Memory Function

cd21LFabJGHI J KLMNOPTQRUVWXYZSABCDEFThank you for purchasing the OMRON M3 Digital Automatic Blood Pressure Monitor.The OMRON M3 is a compact, fully a

Pagina 13 - 3. Using the Unit

185. Optional PartsUsing the Optional AC Adapter1. Insert the AC adapter plug into the AC adapter jack on the rear side of the main unit.2. Plug the A

Pagina 14 - The Icons and Error Messages

19EN6. Technical DataNote: Subject to technical modification without prior notice.Product Description Digital Automatic Blood Pressure MonitorModel OM

Pagina 15

206. Technical Data• This device fulfils the provisions of EC directive 93/42/EEC (Medical Device Directive). • This blood pressure monitor is designe

Pagina 16 - Troubleshooting

216. Technical DataENImportant information regarding Electro Magnetic Compatibility (EMC)With the increased number of electronic devices such as PC’s

Pagina 17

227.Some Useful Information about Blood PressureWhat is Blood Pressure?Blood pressure is a measure of the force of blood flowing against the walls of

Pagina 18 - Maintenance

237. Some Useful Information about Blood PressureENWhy is it a Good Thing to measure Blood Pressure at Home?Many factors such as physical activity, an

Pagina 19 - • If the unit is wet

247. Some Useful Information about Blood PressureClassification of Blood Pressure by the World Health Organization The World Health Organization (WHO)

Pagina 20 - 5. Optional Parts

1ENImportant Safety InformationConsult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis.Please read this se

Pagina 21 - 6. Technical Data

2Important Safety Information(AC Adapter Usage) • Use only the original AC adapter (optional) designed for this unit. Use of unsupported adapters may

Pagina 22

3EN1. OverviewMain unitDisplayO/I START ( ) buttonMemory buttonUp/Down ( ) buttonsBuzzer and Date/Time setting ( ) buttonAir JackBattery compartmentAC

Pagina 23

42. Preparation2.1Installing/Replacing the Batteries1. Remove the battery cover.2. Insert four “AA” batteries as indicated in the battery compartment

Pagina 24 - What is Arrhythmia?

52. PreparationEN2.2Setting the Buzzer/ Date and Time1. Press the button.2. Set the Buzzer.3. Set the monitor to the correct date and time before ta

Pagina 25

63. Using the Unit3.1Applying the Arm CuffRemove tight-fitting clothing or tight rolled up sleeve from your upper arm.Do not place the cuff over thick

Pagina 26

73. Using the UnitEN3.2How to Sit CorrectlyTo take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. N