SpotArm™ Type Blood Pressure MonitorModel i-Q142• Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual de instruccione
102. Preparation2. Preparation2.1 Connecting the AC AdapterCaution: Use only the AC adapter designed for this unit.1. Insert the plug of the AC adapte
112. PreparationEN2.2 Setting the Date and TimeYour blood pressure monitor automatically stores up to 84 individual measurement values with the date a
122. Preparation2. Press the Weekly average buttons to adjust the year setting.• Press the Evening average button once to increase the setting by one
132. PreparationEN5. Press the Memory button to confirm the setting when the desired number appears on the display.The month is set and the day digit
142. Preparation8. Set the hour and minutes in the same way as the date settings.Press the Weekly average buttons to adjust the digits for the hour an
152. PreparationENAdjusting the Date and Time SettingNote: If you need to change the date and time for some reason, adjust the date and time between 1
163. Using the UnitOperating instructions3. Using the Unit3.1 How to Sit Correctly When Taking a MeasurementCorrect posture during measurement is nece
173. Using the UnitENNote: You can take a measurement on either your left or right arm. The blood pressure can differ between the right arm and the le
183. Using the Unit3.2 Place Your Arm Through the Arm CuffRemove the cushion sheet before using the unit for the first time.Take readings with your ba
193. Using the UnitEN2. Place your left arm through the arm cuff.Notes:• Do not remove the cuff lining in the arm cuff.• If the cuff lining becomes de
2 ContentsBefore using the unitIntroduction ... 3 Important Safety Infor
203. Using the Unit3.3 Taking a ReadingTry to take readings at the same time each day (within 1 hour after waking up is recommended). This will make t
213. Using the UnitENThe user alternates with each press of the User ID selection button , as shown below.Notes:• If “G” is selected, the measurement
223. Using the Unit5. Press the START/STOP button once to start measurement.Do not move your arm and remain still until the entire measurement process
233. Using the UnitENTo cancel a measurementIf you press the O/I or START/STOP button while the cuff is inflating, measurement stops and the arm cuff
243. Using the Unit6. Check the measurement results.The measurement results are automatically stored in the memory. (Refer to Chapter 3.5.)Note: If “G
253. Using the UnitENIf “E” or “EE” is displayedMeasurement could not be completed successfully. (Refer to Chapter 4.1.)Wait 2-3 minutes before taking
263. Using the UnitSymbol Information:• If your systolic or diastolic pressure is outside the standard range, the Heartbeat symbol ( ) will blink when
273. Using the UnitENWhat is Irregular Heartbeat?An irregular heartbeat is a heartbeat rhythm that varies by more than 25% from the average heartbeat
283. Using the Unit3.4 Instructions for Special ConditionsIf your systolic pressure is known to be more than 170 mmHg or if you failed to measure bloo
293. Using the UnitEN3.5 Using the Memory FunctionThe unit is designed to store the blood pressure and the pulse rate in the memory for two people (us
3 IntroductionENBefore using the unitIntroductionThank you for purchasing the OMRON i-Q142 Intellisense SpotArm™ Type Upper Arm Blood Pressure Monitor
303. Using the Unit3. Press the Memory button .The average value is shown and the Average symbol ( ) appears above the Memory symbol ( ) on the displ
313. Using the UnitENMorning and Evening Weekly AveragesThe unit calculates and displays weekly averages for measurements taken in the morning ( ) and
323. Using the UnitAbout the Weekly AveragesMorning Weekly AverageThis is the average for measurements taken during the morning (4:00-9:59) between Su
333. Using the UnitENTo Display Morning and Evening Averages1. Press the O/I button to turn the power on.2. Press the User ID selection button to se
343. Using the UnitNotes on Display CombinationsIn addition to the Morning average and Evening average symbols, the unit may also display the Morning
353. Using the UnitENThe Morning hypertension symbol ( ) appears if the weekly average for morning measurements is above 135/85 mmHg.In this case the
364. Handling Errors and ProblemsCare and maintenance4. Handling Errors and Problems4.1 Error MessagesNote: If you change your posture, or move, durin
374. Handling Errors and ProblemsEN4.2 TroubleshootingProblem Cause RemedyThe reading is extremely high (or low).Is your arm placed through the arm cu
384. Handling Errors and ProblemsOther.Turn the power off, then repeat measurement.If the problem persists, contact your OMRON distributor or Customer
395. Maintenance and StorageEN5. Maintenance and StorageTo protect your unit from damage, please observe the following:• Do not subject the unit to ex
4 Important Safety InformationImportant Safety InformationConsult your doctor during pregnancy, arrhythmia and arteriosclerosis.Please read this secti
405. Maintenance and StorageStoragePlease observe the following storage conditions.• Do not subject the unit to extreme temperatures, humidity, moistu
416. Optional PartsEN6. Optional PartsUsing the optional softwareOmron’s blood pressure management software allows you to view, process and print data
426. Optional Parts1. Open the PC/printer port cover.2. Plug the PC/printer port connector plug (small connector) into the PC/printer port on the main
436. Optional PartsENUsing the optional printerPlease read attached “Instruction Manual” before using the printer.1. Remove printer cable plug from th
447. Technical Data7. Technical DataNote: Subject to technical modification without prior notice.• This OMRON product is produced under the strict qua
457. Technical DataENThis marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at
468. Some Useful Information about Blood Pressure8. Some Useful Information about Blood PressureWhat is Blood Pressure?Blood pressure is a measure of
478. Some Useful Information about Blood PressureENClassification of Blood Pressure by the World Health Organization The World Health Organization (WH
488. Some Useful Information about Blood PressureManufacturerOMRON HEALTHCARE Co., Ltd.53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPANEU-repres
5 Important Safety InformationEN(General Usage)• Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not u
6 Important Safety Information• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Secti
71. OverviewEN1. OverviewMain UnitA. Arm cuff release button Press this to open as shown above.B. Cuff liningC. Memory button D. Weekly average (Morni
81. OverviewDisplayM. Systolic blood pressureN. Diastolic blood pressureO. Pulse displayP. Date/Time displayQ. Week displayR. Deflation symbolS. Postu
91. OverviewENPackage ContentsAE. AC adapter • Instruction manual• Quick guide• Guarantee card• Blood pressure pass• Instruction Manual for Optional P