Omron NE- C801KD Manuale Utente

Navigare online o scaricare Manuale Utente per Compressori d'aria Omron NE- C801KD. Omron NE- C801KD User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Compressor Nebuliser
Model NE-C801KD
• Instruction Manual
• Mode d’emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
TMTM
IM-NE-C801S-KDE-03-11/2011
5332892-4C
NE-C801S-KDE_A_M08_110318.pdf
12F1380
EN
FR
DE
IT
ES
NL
AR
RU
NE-C801S-KDE_A_M_Cover.fm Page 1 Monday, June 4, 2012 3:53 PM
Vedere la pagina 0
1 2 3 4 5 6 ... 25 26

Sommario

Pagina 1 - NE-C801KD

Compressor NebuliserModel NE-C801KD• Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual de instrucciones• Gebruiksa

Pagina 2 - QUICK MANUAL

101.Know your unitAccessories• Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual de instrucciones• Gebruiksaanwijzi

Pagina 3 - 4. Attaching air tube

11EN2. Preparing the nebuliser for useWarning:• Clean and disinfect the nebuliser kit, kids accessory, mask or mouthpiece before using them for the fi

Pagina 4 - Introduction

122.Preparing the nebuliser for use2.2 Adding medication and assembling the parts1. Remove the mask or mouthpiece, kids accessory and cap from the neb

Pagina 5 - Intended use

132.Preparing the nebuliser for useEN6. Attach the cap, kids accessory, mask or mouthpiece to the nebuliser kit.1) Attach the cap to the inhalation ai

Pagina 6 - Important safety instructions

143. Taking medication1. Hold the nebuliser kit as indicated on the right.Caution: Do not tilt the nebuliser kit so that it is at an angle of greater

Pagina 7

153.Taking medicationEN4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug t

Pagina 8

164. Cleaning and daily disinfecting4.1 CleaningFollowing the cleaning instructions after each use will prevent any remaining medication in the tank f

Pagina 9 - 1. Know your unit

174.Cleaning and daily disinfectingEN4.2 Disinfecting the nebulising partsAlways clean before disinfection. (See Section 4.1 “Cleaning”)Always disinfe

Pagina 10 - Accessories

184.Cleaning and daily disinfectingUse the table below as a guideline to select a method for disinfecting O: applicable ×: not applicable* an example

Pagina 11 - Operating instructions

19EN5. Maintenance and storageTo keep your device in the best condition and protect the device from damage follow these directions:Caution:• Do not le

Pagina 12

QUICK MANUALPlease read entire manual before using the device.Warning:Clean and disinfect all the parts before using them.page 16-181. Adding medicati

Pagina 13 - 7. Attach the air tube

206. Changing the air filterIf the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one.1. Pull

Pagina 14 - 3. Taking medication

21EN7. TroubleshootingCheck the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instr

Pagina 15 - Warning:

228. Technical data Notes:• Subject to technical modification without prior notice.• This OMRON product is produced under the strict quality system of

Pagina 16 - Mild Detergent

238.Technical dataENTechnical data for the OMRON NE-C801KD Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit:Result of cascade

Pagina 17 - Handling the Vaporiser Head

248.Technical dataImportant information regarding Electro Magnetic Compatibility (EMC)With the increased number of electronic devices such as PC’s and

Pagina 18

25EN9. Optional parts and accessoriesV.V.T. Nebuliser Kit N-01 & Mouthpiece SetModel: C801-NSET3Order No.: 9515573-6V.V.T. Nebuliser Kit N-01 &am

Pagina 19 - 5. Maintenance and storage

26Made in ChinaManufacturerOMRON HEALTHCARE Co., Ltd.53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPANEU-representativeOMRON HEALTHCARE EUROPE B.

Pagina 20 - 2. Change the air filter

3. Connecting AC adapter4. Attaching air tubeAttach the air tube to the main unit and to the nebuliser kit.When do so, twist and push it firmly.page 1

Pagina 21 - 7. Troubleshooting

4ContentsBefore using the deviceIntroduction ...

Pagina 22 - °C to +40°C 30% to 85% RH

5ENIntended useMedical Purpose This product is intended to be used for inhaling medication for respiratory disorders.Intended User • Legally certified

Pagina 23 - Cumulative Undersize %

6Important safety instructionsRead all the information in the instruction manual and any other literature included in the box before using the device.

Pagina 24

7ENCaution: Indicates a potentially hazardous situation which if not avoided, may result in minor or moderate injury, or physical damage. (Usage)• Pro

Pagina 25 - Mouthpiece

8(Risk of electrical shock) • Always unplug the AC adapter from the power outlet after use and before cleaning.• Plug the device into the appropriate

Pagina 26 - Subsidiary

9EN1. Know your unitAir Filter Cover*Air filter insidePower ConnectorCompressor (Main Unit)CapInhalation Air Inlet Inhalation TopVaporiser HeadMedicat

Commenti su questo manuale

Nessun commento